Page 1 - User’s Guide

- 1 - Monnit Wireless Sensors Serial MODBUS (RTU/ASCII) Gateway For Version 3.0 User’s Guide

Page 2 - Contents

- 10 - 3.0 MODBUS Protocol Implementation See http://MODBUS.org/docs/MODBUS_Application_Protocol

Page 3

- 11 - 3.3 Communication Defaults  MODBUS slave ID or MODBUS address: 95 or 0x5F  MODBUS-RTU,

Page 4

- 12 - 4.0 Using the Gateway - Coil and Register Map This device has various coils and registers

Page 5 - Example Network Integration

- 13 - 4.2 Resetting the Gateway Write the “RST_DEVICE” Gateway Coil (Function Code address = 2, R

Page 6

- 14 - 4.6 Viewing and Modifying MODBUS Communication Settings The BAUDRATE Gateway Reg

Page 7 - Hardware

- 15 - 4.7 Viewing Registered Wireless Devices The WD_CNT Gateway Register (Function Code addres

Page 8

- 16 - To delete a wireless device from the list, write a 0,0 into the SLOT and the device will be er

Page 9 - Indicator Light Sequences:

- 17 - The purpose of these registers is to allow for efficient access to the remote wireless device’

Page 10 - 3.2 Multi-byte Formatting

- 18 - 4.12 Configuring Wireless Devices (Standard Requests) For a user to view and mod

Page 11 - 3.5 Factory Reset Jumper

- 19 - 5.0 Upgrading Gateway Firmware Gateway Versions 3.0.0.0 and above are remotely upgradeable

Page 12 - Coil and Register Map

- 2 - Contents 1.0 - Serial MODBUS Gateway Overview Features Example Network Integration

Page 13

- 20 - Reference Section Complete Gateway Features and Resource Mapping Reference Through the MODBU

Page 14

- 21 - RST_FACTORY 5 4 Writing True (1) to this coil will force all settings to Factory defaults. A

Page 15 - 40102 / 101 43527

- 22 - Ref.2 - Wireless Device Coils This section defines the location and function of all the remot

Page 16 - (Fast Read Method)

- 23 - PENDING_CFG 2 True (1) denotes that one or more registers have been modified from their origin

Page 17 - (Advanced method)

- 24 - Example Value: 0 (no sensors registered, factory reset condition) Example Value: 10 (10 Regi

Page 18 - (Standard Requests)

- 25 - CHANM_H 40009 8 CHANM_L 40010 9 The configurable channel mask is a UInt32 bit-field that

Page 19

- 26 - Ref.4 - Wireless Device List Registers The WDL register stores the serial identifier of the r

Page 20 - Ref.1 - Gateway Coils

- 27 - The format of these records are: Name Offset Description AGE 0 time in seconds when the wire

Page 21

- 28 - Field Name Offset Description ID_H 0 ID_L 1 Wireless device’s globally-unique identifier. Com

Page 22 - Description

- 29 - CFG_ CHANM_H 17 CFG_ CHANM_L 18 Configurable Channel Mask is a UInt32 bit-field that represe

Page 23 - Ref.3 - Gateway Registers

- 3 - 1.0 Serial MODBUS Gateway Overview The Monnit Serial MODBUS Gateway (SMG) acts as a data con

Page 24

- 30 - CFG_ PROFILE_TYPE 24 Value that selects what profile specific device type is recognized by the

Page 25

- 31 - CFG_INT_TYPE_ CALVAL_1_H 32 CFG_INT_TYPE_CALVAL_1_L 33 CFG_INT_TYPE_ CALVAL_2_H 34 CFG_INT_TYP

Page 26 - Ref.5 - Fast Read Registers

- 32 - Error Reporting, Troubleshooting and Support For technical support and troubleshooting

Page 27

- 33 - (b) As a condition to Monnit’s obligations under the immediately preceding paragraphs, Custome

Page 28

- 34 - Certifications United States FCC This equipment has been tested and found to comply with the

Page 29

- 35 - Canada (IC) English Under Industry Canada regulations, this radio transmitter may only opera

Page 30

- 36 - Monnit Corporation 7304 South Cottonwood Suite #204 Midvale, Utah 840

Page 31

- 4 - This device has been designed to operate with an approved antenna listed on page 11, and h

Page 32 - Warranty Information

- 5 - Features  Works with Monnit 900, 868 and 433MHz Sensor Networking Solutions  Communicates w

Page 33

- 6 - Monnit Serial MODBUS Gateway Specifications General Monnit APN Interface Support RFSC1 Module

Page 34 - Certifications

- 7 - 2.0 Connecting The Serial MODBUS Gateway Hardware This section contains details

Page 35 - Canada (IC)

- 8 - 2.1 Connecting the Serial MODBUS Gateway to the USB Programming Dongle: Monnit

Page 36

- 9 - 2.2 Serial MODBUS Gateway Indicator Lights System - Indicates gateway status. A green l