MonnitLink™ Ethernet Gateway Quick Start • Create a Monnit user account with assigned wireless gateways and sensors. • Attach the antenna to t
PAGE 10Devices to NotifyIf you have a Monnit Control or Notier A/V device on your network, you will also see a “Devices to Notify” tab. This will all
6. Calibrating Sensor DataCertain wireless sensors can be calibrated for more accurate readings (ex. temperature sensors). If calibration is possible
PAGE 125. Advanced Settings and Interfacing with the Monnit Ethernet Gateway Through iMonnit.1. Ethernet Gateway Edit ScreenWhen you log into the
To set the Static IP, uncheck the Use DHCP box and ll in the settings:The force transmit on Aware box tells the gateway to deliver immediately the me
PAGE 14MODBUS TCP InterfaceUse MODBUS TCP software to pull in gateway and sensor data. Monnit provides a register map. Check the box to make the inter
Data 1 Sensor Data Field 1 40109 108 Data 2 Sensor Data Field 2 40110 109 Data 3 Sensor Data Field 3 40111 110 Data 4 Sensor Data Field 4 40112 111 D
PAGE 16Ethernet Gateway MIB tree with a short description of each eld:EGW Data Description*GW Section Gateway Section*GW Serial Gateway Serial ID*Ver
6. Setting up the Ethernet gateway for use with iMonnit ExpressiMonnit Express (PC Software) SetupVisit http://www.monnit.com/support/downloads/ to do
PAGE 18• Click on “About”, then “Local IP Addresses” and make note of the IP address that your computer is using on your network. • Connect
• When nished, click the “Reboot” button on the top right side of the page to restart the gateway. • When the lights begin ashing on the gatewa
1. Create a Monnit User Account and Setup Sensor Network If this is your rst time using the iMonnit online system site, you will need to create a ne
Error Reporting, Troubleshooting and Support For technical support and troubleshooting tips please visit our support library online at http://www
(b) As a condition to Monnit’s obligations under the immediately preceding paragraphs, Customer shall return Products to be examined and replaced to M
CerticationsUnited States FCC This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant to Part 15 o
PAGE 23Canada (IC) EnglishUnder Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser
Monnit Corporation7304 South CottonwoodSuite #204Midvale, Utah 84047801-561-5555www.monnit.comAll trademarks are property of Monnit. © 2009-2014 Mon
PAGE 37. Conrmation Screen.When you have nished adding the sensor, you will see a conrmation screen. At this point you can assign notications to t
3. Conguring The Ethernet Gateway The Ethernet Gateway collects data from all sensors within range and is precongured to batch deliver the sensor me
4. Using The iMonnit™ Online Wireless Sensor System1. Understanding The Online InterfaceWhen you log into the online system, the default view shows al
PAGE 6To the left side of each sensor row is an indicator to help you understand the current status of the sensor. Sensor is checking in and within us
PAGE 73. Conguring Sensor SettingsTo edit a sensors operation settings, click on the sensor overview row to display the de-tails view. Click on the “
4. Sensor and/or Gateway Notication(s).Notications for a single sensor can be created, deleted or edited by clicking the “Notications” tab in a sen
• Advanced Notications - Allows the user to set notications based on advanced rules, such as comparing past data points with the current one to det